High Efficiency Atomizer Transducer

High efficiency atomizer transducer uses patented ultrasonic focus technology to enhance the efficiency of transducer. For example, by using conventional ultrasonic atomizer transducer, a 12V ultrasonic nebulizer with fog output 40ml/h usually require the power 12W at least. By using high efficiency atomizer transducer, it only need 5W. Therefore, the high efficiency atomizer transducer is especially suitable for portable nebulizer and ultrasonic inhaler.

In addition, due to lower heating lost in high efficiency model, the transducer has a longer lifetime than conventional model. The high efficiency transducers with Siansonic's patented nickel electrode coating can continuously operate with good performance for 15000-30000 hours at normal condition.

 


  • High efficiency: generally 60% power saved

  • Long lifetime: > 15000 hours

  • Tiny fog particle (diameter 1 - 4 µm).

  • Capability of low power operation: 5V-12V, 2W-5W

  • High stable electrode coatings: nickel or anti-corrosive coating

  • Diameter: 12mm,15mm, 20mm

  • Frequency: 1.7MHz, 2.0MHz, 2.4MHz, 2.5MHz, 2.6MHz, 3.0MHz

  • Electrode Coating: Nickel, Anti-corrosive

  • Accessories: Wires, Rubber ring, Metal housing, Connector

  • The transducers (except the anti-corrosion model: coating E) should work in drinking water or similar liquids. If liquids have an acidity of less than pH5, it could makethe output performance decay,even permanently destroy the transducer. Therefore, the transducers cannotwork in the liquid that is excessively acidic (pH<5).<

  • Provide a protective “low water” shut-off circuit. The transducers should NEVERworkwithout liquid in contact with them even though in a very short time (a few seconds).

  • Design a circuit to assure no voltage difference appears between surface of transducer and water. We highly recommend the float switch for liquid level control. PLEASE DON’TUSEELECTRODECONTROL FOR “NO WATER” PROTECTION! OTHERWISE THE TRANSDUCER COATING CAN BE ELECTROLYSED OUT.

  • The surface of transducers should be cleaned at times. It will NOT be considered as the quality problem on transducers, if the atomizing effect of transducers decays due to substances contained in liquid such as Ca, Na, Mg and Si etc. adhering to the transducers surface.